Seitenansicht 18
17
Slave Normal Operation
Slave normal operation is a signal to confirm that the AD-4408A is connected to the power
and is in normal operating conditions. During normal operation, the signal is reversed at a
0.5 to 1 second interval.
Slave normal operation
Fig.7 Slave normal operation signal
Error status flag
If an AD-4408A error has occurred, the slave ready bit will be turned OFF and the error
status flag will be turned ON to convey to the master device that an error has occurred.
The master device will turn the error reset flag ON to request resetting the error status
flag.
Fig.8 Resetting the error status flag
Table 8 Command bits / Status bits
Memory Description
Sixth word of OUT data Bit 2 Error reset flag
Bit 2 Slave normal operation
Bit 3 Slave ready
Tenth word of IN data
Bit 4 Error status flag
0.5 to 1 sec
Slave read
y
Error status flag
Error reset flag
Seitenansicht 18