60
CHAPTER 9 OPTIONS
There are the following external input/output options.
Note) The 4401 has only one slot for OP-01, OP-03 or OP-04. Therefore only one of them can be installed.
• OP-01 BCD output
• OP-03 RS-422/-485 input/output
• OP-04 RS-232C input/output
• OP-05 Setpoint unit (Setpoint setting thumbwheel switch, common to the AD4323)
• OP-07 Analog output (100 times/sec. high-speed output, can be scaled optionally)
9-1 OP-01 PARALLEL BCD OUTPUT
Setting of the BCD output is done with the general functions, BCDF-01 through BCDF-05.
Setting
BCDF- Name Default
Parameter Description
1 Displayed weight
2 Gross
3 Net
01 Output data 1
4 Tare
1 Stream
2 Auto print
02 Data transfer mode 1
3 Manual print
1 Positive logic
03 Data output logic 2
2 Negative logic
1 Positive logic
04 Strobe output logic 2
2 Negative logic
CONNECTOR FOR OP-01 BCD OUTPUT (INCLUDED WITH THE OP-01 ACCESSORIES.)
Parts Name Q'ty Parts Number Description
Connector
1 JI-361J040-AG
FCN361J040-AU (or AG),Fujitsu
Connector cover
1 JI-360C040-B
FCN360C040-B, Fujitsu
.
.
/-
/-
2