A&D Digital Comparator AD-8512 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messen, Testen & Steuern A&D Digital Comparator AD-8512 herunter. A&D AD-4401 High-Performance Digital Indicator Brochure Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
100 Times/Second High-Speed Sampling
High Display Resolution to 16,000 Counts
Up to 1,000,000 Counts of A/D Resolution
Monitor and Control Weighing and Batching
with External or Internal Resolution
Fuzzy and Automatic Free Fall Compensation
(AFFC) for Consistently Accurate Batching
Results
Enter Control Setpoints Through Front Keys or
Remotely Through External Thumb-Wheels
Automatic Weight and/or Count Accumulation
Sub Display Provides Feedback on All Setpoints
and Simplies Calibration
Supplementary Flow Function Assures Accurate
Performance on Each Batch
A Host of Communications Capabilities:
RS-232C, RS-422/485, BCD, Analog Output
and Standard 4-20mA Current Loop
AD-4401
HIGH-PERFORMANCE
DIGITAL INDICATOR
The AD-4401 high-
performance weighing and
batching indicator is ideal for
batching, loss-in-weight, check
weighing or simple static
weighing applications.
HIGHLIGHTS
Connect Up to 10 AD-4401’s with RS-422/485
Compact DIN Size Housing Speeds Installation
and Reduces Space
Digital Span Calibration Enhances Technical
Support and Difcult Installations
Splash-Proof Front Panel and Keys (lP-65).
High Sensitivity 0.3µV/Division for More
Accurate Measurements
Automatic Batching and Customer Programming
Capability
Bright, Clear Fluorescent Displays
Hold and Peak Hold Functions
User Programmed Timer Settings and Alarms
Improve Operational Safety and Performance
Weigh-In and Loss-In-Weight Batching
NETWORK UP TO 10 UNITS
#10
#01
#02
by
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - DIGITAL INDICATOR

100 Times/Second High-Speed Sampling High Display Resolution to 16,000 Counts Up to 1,000,000 Counts of A/D Resolution Monitor and Control Wei

Seite 2 - REAR PANEL FEATURES

STANDARD SERIAL OUTPUT:20mA current loop output to A&D’s peripheral deviceSETPOINT:Changes settings of each comparison value using a thumbwheel or

Seite 3 - SPECIFICATIONS

SPECIFICATIONSANALOG & A/D CONVERSIONExcitation 10V ±5%, 230mA, Remote Sensing, Maximum 8 x 350Ω LoadcellsInput Sensitivity Minimum of 0.3μV/Divis

Seite 4 - DIMENSIONS

WESTERN AUSTRALIA (HEAD OFFICE):PHONE: (08) 9259 5535www.accuweigh.com.auSOUTH AUSTRALIA OFFICE:PHONE: (08) 8447 5011VICTORIA OFFICE:PHONE: (03) 9548

Kommentare zu diesen Handbüchern