- 46 - AD-4430B
7.6.4. The List Of The Calibration
Function No.
Parameter
and range
Function
name
Description
Default
value
User
setting
MEMO
CAL02
0 to 0.0000
Decimal point
position
Decimal point position of the weight value
0 0.00 0.0000
0.0 0.000
0
CAL03
1 to 50
Minimum
division
Minimum division (d) of the weight value
1 2 5 10 20 50
1
CAL04
1 to 99999
Weighing
capacity
Weighing capacity of the module.
Weighing is possible up to the value of this
setting plus 8 d. If the value exceeds this,
overflow will occur and will not be displayed. The
decimal point position is the same as the setting
of CAL02.
70000
CAL05
0 to 100
Zero
adjustment
range
Range to enable zero adjustment by the
(ZERO) key Expressed as a percentage of
the weighing capacity with the calibration zero
point as the center. For example, if this is set to 2,
the value in the range of ±2% of the weighing
capacity with the calibration zero point at the
center will be to zero. When a power-ON zero is
performed, the initial zero point will be the center.
2
CAL06
0.0 to 5.0
Zero tracking
time
Performs zero tracking using this setting in
combination with the setting of the zero tracking
band CAL07. When 0.0, zero tracking will not be
performed. Unit : Second in 0.1 increments.
0.0
CAL07
0.0 to 9.9
Zero tracking
band
Performs zero tracking using this setting in
combination with the setting of the zero tracking
time CAL06. When 0.0, zero tracking will not be
performed. Unit : d (minimum division) in 0.1
increments.
0.0
CAL08
0.0 to 9.9
Stability
detection time
Performs stability detection using this setting in
combination with the setting of the stability
detection band CAL09. When 0.0, stability
detection will not be performed. (Stable all the
time) Unit : Second in 0.1 increments.
1.0
CAL09
0 to 9
Stability
detection
band
Performs stability detection using this setting in
combination with the setting of the stability
detection time CAL08. When 0, stability
detection will not be performed. (Stable all the
time) Unit : d (minimum division).
2
CAL10
0 to 1
Tare and zero
adjustment
when
unstable
Tare and zero adjustment when the weight
value is unstable.
0 : Disables both functions.
1 : Enables both functions.
1
CAL11
0 to 1
Tare when
the gross
weight is
negative
Tare when the gross weight is negative.
0 : Disables tare.
1 : Enables tare.
1