Seite 2

8  The TARE switch will tare the scale and subtract the weight to zero as a tare weight when the weight is a plus value. In this case the ZERO◄ an

Seite 3 - CONTENTS

9 6. SELECTING A WEIGHING UNIT 6.1. Storing The Weighing Unit 1. Touch the ON/OFF switch while touching and holding the TARE switch in order

Seite 4 - 1. SAFETY PRECAUTIONS

10 7. COUNTING MODE Determines a unit weight (the weight of one piece) from a known sample quantity, and calculates how many pieces are on the weigh

Seite 5 - 2. PARTS DESCRIPTION

11 8. COMPARATOR The scale has three-, five- and seven-level comparators. Each comparator mode compares the weight value against the preset limit va

Seite 6 - 3. PREPARATION

12 8.1. The Formula To Compare Comparison is performed using the formula listed below and the results are output. Five-level comparator mode Resu

Seite 7 - 4. DISPLAY AND SYMBOLS

13 Seven-level comparator mode (portion weighing mode) Results Comparison formula LED display None Displayed value < Level 1 lower limit, or

Seite 8 - TARE switch to

14 8.2. Entering The Comparator Values 1. In the weighing mode, touch and hold the UNITS switch to enter the comparator value setting mode. 2.

Seite 9 - 5. OPERATION

15 9. AUTO-TARE The SJ-WP series has an auto-tare function to be used with the comparator mode enabled. If the weight values are in the OK range of

Seite 10

16 10. CALIBRATION Adjusts the scale for accurate weighing. Calibrate the scale in the following cases.  When the scale is first installed.  When

Seite 11 - SELECTING A WEIGHING UNIT

17 Tap the UNITS switch to select an item and Tap the TARE switch to execute it. To exit from the calibration mode, touch the sw

Seite 12 - 7. COUNTING MODE

© 2013 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted

Seite 13 - 8. COMPARATOR

18 10.3. Calibration Using A Weight Prepare a weight, preferably a weight with the same value as the weighing capacity of the scale to be calibrated.

Seite 14 - Three-level comparator mode

19 10.4. Restoring The Calibration Data To The Factory Set Values If the gravity acceleration value or calibration data is changed unintentionally, r

Seite 15

20 11. FUNCTION SETTINGS The scale has function settings to specify the scale performance. The parameters set in the function settings are maintained

Seite 16

21 11.2. Restoring The Function Settings To The Factory Set Values 1. Turn the power OFF. 2. Touch and hold the TARE switch and touch the sw

Seite 17 - 9. AUTO-TARE

22 11.3. Function List Item Parameter Description  All function is enable. Enable function: ON/OFF key, zero key, Tare key, Comparator settin

Seite 18 - 10. CALIBRATION

23 Item Parameter Description  Five-level (Result LED blinks.) Five-level (Result LED lights.) Three-level (Result LED blinks.) Three-level

Seite 19

24 12. MAINTENANCE 12.1. Notes On Maintenance  Do not disassemble the scale. Contact your local A&D dealer if the scale needs service or repa

Seite 20

25 13. SPECIFICATIONS Specifications Model SJ-3000WP SJ-6000WP SJ-15KWP SJ-30KWP Capacity 3 kg 6 kg 15 kg 30 kg 0.001 kg 0.002 kg 0.005

Seite 21

26 Other weighing units Model SJ-3000WP SJ-6000WP SJ-15KWP SJ-30KWPCapacity 3000 g 6000 g 15000 g 30000 g 1 g 2 g 5 g 10 g 0.5 g* 1 g* 2 g* 5

Seite 22 - 11. FUNCTION SETTINGS

27 14. GRAVITY ACCELERATION Values of gravity at various locations Amsterdam 9.813 m/s2 Manila 9.784 m/s2 Athens 9.807 m/s2 Melbourne 9.800 m/s2

Seite 23

1 CONTENTS 1. SAFETY PRECAUTIONS ... 2 2. PARTS DESCRIPTION...

Seite 26 - 12. MAINTENANCE

3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013, JAPAN Telephone: [81] (3) 5391-6132 Fax: [81] (3) 5391-6148 A&D ENGINEERING, INC.

Seite 27 - 13. SPECIFICATIONS

2 1. SAFETY PRECAUTIONS All safety messages are identified by the following, "WARNING" or "CAUTION", of ANSI Z535.4 (American

Seite 28 - Other weighing units

3 2. PARTS DESCRIPTION Sealing diagrams Screwdriver Use this screwdriver to open or close the battery cover.

Seite 29 - 14. GRAVITY ACCELERATION

4 3. PREPARATION 3.1. Installing / Exchanging Batteries The batteries are not included with the product. Prepare 6 x "D" size (R20P or LR

Seite 30 - World map

5 4. DISPLAY AND SYMBOLS 4.1. Display 4.2. Symbols Symbol Description STABLE Turns on when the weight value is stable. NET ◄ Tur

Seite 31

6 4.3. Operations And Functions Of Switches Switch Description When the scale is turned off: Touch the switch to turn ON the scale. The scale will

Seite 32

7 5. OPERATION 5.1. Basic Weighing Operation 1. Touch the switch to turn the power ON. All the symbols except the comparator LEDs are displayed