WM+PD4001368 FFSS--ii SSeerriieess CChheecckk WWeeiigghhiinngg SSccaalleess OOppttiioonn OP-02 / OP-03 / OP-04
- 9 - Set a preset tare weight. (No reply for F20-1.) Command P T, + 0 0 1200CLF Decimal point follows the weight display. Reply P T, + 0 0 120
- 10 - Reply O K, + 0 0 1000CLF FS-15Ki : Target weight 1.000 kg will be set. Set a HI limit value or upper limit weight. (No reply for F20-1.)
- 11 - Command M L, 0 1 , +001000,+ 0 0 0 2 0 0 , + 0 0 0 1 0 0CLF Reply M L, 0 1 , +001000,+ 0 0 0 2 0 0 , + 0 0 0 1 0 0CLF FS-15Ki :
- 12 - The maximum number of text data is 300 characters. To use the UFC function, the text data has to be sent to the scale from the computer us
- 13 - If you will send more than 2 lines of data, attach “&” to the end of the first line. Then, the scale considers the data to be continued.
- 14 - 3. OP-04 RS-422 / 485 / RELAY OUTPUT This interface allows a personal computer to connect and control up to 16 FS-i scales, and the relay out
- 15 - Installation is similar to the OP-03. See “2-1. Installation”. Set the function parameters F04, F05, F06, F18, F19 and F20 according your
- 16 - Example of connection RS-422 RS-485 The polarity (A, B) of the host computer signal depends on model. Check the t
- 17 - Examples of command and reply (“_” shows “Space” (20H).) Following examples are for F20-0 (Reply to command is sent.) The address ## = 23
- 1 - Contents 1. OP-02 BATTERY... 2 1-1. Using the OP-02 S
- 2 - 1. OP-02 BATTERY 1-1. Using the OP-02 SLA Battery The scale can be operated with an SLA (Sealed Lead Acid) battery that will be commercially
- 3 - 1. Disconnect the main power cord from the outlet. 2. Remove the ten hexagon head screws and open the rear cover. Take care not to drop the re
- 4 - 2. OP-03 RS-232C / RELAY OUTPUT This interface allows the FS-i series to be connected with a multifunction printer or a personal computer, and
- 5 - 1. Disconnect the main power cord from the outlet. 2. Remove the ten hexagon screws and open the rear cover. 3. Connect the cable from external
- 6 - Circuit diagram Data format S T , + 0 0000.00_k g CR LF Header Data Unit Te
- 7 - Out of rage (+) O L,+9999999 9 _ k gCRLFData output mode (F06) Stream Mode (F06-0) Data is sent continuously. The data-update rate is appro
- 8 - Command Definition Notes CT Clear tare weight. Including preset tare. ?PT Send a preset tare weight in-use. ?TR Send a tare weight in-use